Possess battery pack voltage, current, temperature acquisition and monitoring functions;
It can provide protection functions such as overcharge, overdischarge, overcurrent, high temperature, low temperature, short circuit, and abnormal internal communication for the battery pack;
It has the functions of accurate SOC measurement and SOH health status statistics during the charging and discharging process;
Possess the cell equalization function during the charging process;
With a battery data storage unit, it can classify and store battery alarms and operating data;
It has RS485 communication, supports the MODBUS protocol of the power exchange cabinet, and can communicate with Tianbangda host computer to realize the function of monitoring data and configuring parameters;
This product can be equipped with a 4G wireless communication module. After the wireless module is equipped with a SIM card, the battery pack monitoring information can be uploaded to the monitoring background to monitor the battery information.
Support GPS and Beidou dual-mode positioning;
With functions such as remote upgrade and parameter modification;
This product can be equipped with BLE4.2 Bluetooth module, supports GATT protocol, the battery is used as a server, and the power exchange cabinet/mobile APP is used as a client to obtain battery device information.
| Working temperature | -20℃~+65℃ | |||||
| Cooling method | Natural heat dissipation | |||||
| Dimensions (L*W*Dmm) | Special car, can be customized | |||||
| Protection level | IP67 (Complete with PACK) | |||||
| Battery voltage | UP 60V/72V | |||||
| Rated charge/discharge power | UP 3000W (can be customized) | |||||
| Wireless communication | 4G/BT/dual-mode positioning/NB | |||||
| Communication interface | CAN/RS485; Line Communication | |||||
| Support battery type | 13-25s, lithium iron phosphate UP 25S/ternary UP21S (cascade AFE) | |||||
| Rated battery voltage | UP 72V | |||||
| Support battery capacity | UP 50Ah/Customized | |||||
| Alarm and protection | Overvoltage, undervoltage, short circuit, overtemperature, low temperature protection, etc. | |||||
| Discharge current limit | UP 1.5C | |||||
| Secondary protection | Onboard level high current controllable fuse | |||||
| Power terminal control | Positive control to reduce isolation devices | |||||
| Communication diagnosis | UDS Diagnostic Protocol | |||||
| Current detection | UDS Diagnostic Protocol | |||||
| SOX super algorithm | Dynamic discharge voltage calibration, charge calibration | |||||
| Anti-ignition | Hardware plus software strategy, never start a fire | |||||
| Model | Share | Tower 3.0 | Tower 4.0 | |||
| Basic parameters | 4815 | 4824/4830 | 4825/4830 | 6020/6030 | UP 4850 | UP 6050 |
| Power type | Share battery swap | |||||
| Number of voltage acquisition strings | 15 skewers | 16 skewers | 16 skewers | 20 skewers | 16 skewers | 20 skewers |
| Temperature sensor | 6-way (4-way/5-way battery/1-way environment/1-way MOS) | |||||
| External communication | Dual RS485 | |||||
| Flow capacity | 15A | 24A/30A | 25A | 30A | 50A | 50A |
| Data storage | 1000 gradually replaced | |||||
| Maximum detection voltage | 60V | 60V | 60V | 72V | 60V | 72V |
| SOC error | ≤5% | |||||
| Range of working temperature | -20℃~70℃ | |||||
| Temperature acquisition accuracy | 50% of the range above the temperature display error ≤ 2 ℃ | |||||
| Current acquisition accuracy | Charge and discharge current error ≤ 2% above 50% of the range | |||||
| Anti-ignition | have | |||||
| Discharge current limiting | \ | \ | have | |||
| 4G wireless communication | \ | Yes, supports the standard TCP communication protocol for tower power replacement, supports remote modification of BMS parameters in the background, and has stable and reliable remote self-upgrade and BMS upgrade capabilities | ||||
| Bluetooth communication | \ | have | ||||